Chemistry ID selection tool, rev=2.57 Configuration used in present fit: ProcessingType=2 NumCellSeries=1 ElapsedTimeColumn=0 VoltageColumn=1 CurrentColumn=2 TemperatureColumn=3 Best chemical ID : 8173 Best chemical ID max. deviation, % : 1.56 Summary of all IDs with max. DOD deviation below 15% Chem ID max DOD error, % Max R deviation, ratio 8173 1.56 0.69 8348 3.01 1.25 8240 3.41 1.82 7476 4.05 1.06 8169 4.06 0.92 8213 4.07 1.53 7821 4.38 1.9 8136 6.17 2.66 8150 6.28 2.83 8135 6.45 3.54 8290 6.72 2.97 7670 6.75 3.57 7994 6.81 3.04 5936 6.81 3.33 8386 7.17 4.78 7706 7.18 3.4 8475 7.32 3.24 8479 7.36 3.76 7841 7.64 0.26 7228 7.85 4.65 5706 8.49 0.75 8217 8.69 4.59 8466 8.83 4.07 5707 8.88 0.67 8163 9.39 5.69 8262 9.53 4.14 7947 9.61 4.71 7473 9.74 4.03 8430 9.77 5.1 8125 9.9 3.86 5410 10.41 0.76 8117 10.64 0.64 8121 10.95 0.35 2153 11 2.73 2708 11.13 0.81 5606 11.29 0.71 8255 11.35 0.63 2161 11.65 0.87 7997 11.66 5.01 8310 11.69 10.09 5432 11.92 4.59 7336 12.04 7.5 2159 13.16 0.93 7477 13.25 5.34 8238 13.5 6.68 2349 13.52 0.83 7427 13.58 0.34 5265 13.59 0.89 5590 13.74 0.93 508 13.74 0.93 5272 14.35 0.92 7028 14.43 7.77 7724 14.72 8.1 7249 14.85 11.41 7802 14.87 5.59 5929 14.87 9 Max. deviations for best ID is within recommended range. Chosen best chemical ID is suitable for programming the gauge. Selection of best generic ID for ROM based devices like bq274xx Device / Family #1 Generic Chem ID Device/ Voltage/ Chemistry max DOD error, % 3142 bq27421-G1D: 4.4V LiCoO2 26.93 354 bq27411-G1C: 4.35V LiCoO2 28.75 128 bq27421-G1A: 4.2V LiCoO2 32.45 312 bq27421-G1B: 4.3V LiCoO2 38.13 Best generic ID 3142 Warning: Generic ID Deviation is so high that it is most likely due to anomaly in the data. Please check that data files have recomended format, units and test schedule Device / Family #2 Generic Chem ID Device/ Voltage/ Chemistry max DOD error, % 1202 bq27621: (default) 4.2V LiCoO2 28.5 1210 bq27621: (ALT_CHEM1) 4.3V LiCoO2 28.59 354 bq27621: (ALT_CHEM2) 4.35V LiCoO2 28.75 Best generic ID 1202 Warning: Generic ID Deviation is so high that it is most likely due to anomaly in the data. Please check that data files have recomended format, units and test schedule Device / Family #3 Generic Chem ID Device/ Voltage/ Chemistry max DOD error, % 3142 bq27426: (ALT-CHEM2) 4.4V LiCoO2 26.93 1202 bq27426: (ALT_CHEM1) 4.2V LiCoO2 28.5 3230 bq27426: (default) 4.35V LiCoO2 29.04 Best generic ID 3142 Warning: Generic ID Deviation is so high that it is most likely due to anomaly in the data. Please check that data files have recomended format, units and test schedule