Chemistry ID selection tool, rev=2.54 Configuration used in present fit: ProcessingType=2 NumCellSeries=1 ElapsedTimeColumn=0 VoltageColumn=2 CurrentColumn=3 TemperatureColumn=1 Best chemical ID : 448 Best chemical ID max. deviation, % : 7.65 Summary of all IDs with max. DOD deviation below 15% Chem ID max DOD error, % Max R deviation, ratio 448 7.65 1.27 482 7.93 2.04 400 8.29 2.77 481 8.41 1.47 426 8.82 1.48 4111 9.09 0.13 459 9.44 3.23 6104 9.45 3.45 4167 9.47 1.77 405 9.76 1.02 4130 9.83 1.5 4159 9.85 0.61 485 9.85 2.19 487 9.85 2.19 461 9.88 1.75 4150 10.04 1.81 4124 10.05 1.41 406 10.07 2.14 442 10.14 1.94 402 10.17 1.08 424 10.17 0.76 486 10.23 0.91 4151 10.3 2.21 2160 10.32 2.16 457 10.38 5.29 4166 10.41 1.07 4106 10.47 0.75 449 10.74 0.63 472 10.76 3.98 4110 10.82 0.57 4131 10.85 2.9 6105 10.87 0.49 414 10.92 1.35 4153 11.17 0.55 4164 11.28 2.43 454 11.47 0.73 411 11.51 1.17 4141 11.67 0.53 429 11.69 0.69 4173 11.74 2.82 403 11.77 1.73 4160 12 0.52 4140 12.09 1.15 4161 12.27 0.68 496 12.33 0.59 4139 12.36 0.65 427 12.57 0.67 451 12.69 2.04 488 12.72 0.62 6106 12.75 2.43 445 12.77 1.62 4134 12.82 1.12 422 12.92 0.63 4118 12.96 2.07 435 13 1.69 4142 13 0.6 6110 13.21 0.38 447 13.24 2.96 419 13.61 1.36 450 13.71 1.96 4172 13.74 2.31 4144 13.85 2.53 425 14.06 1.89 491 14.22 2.6 413 14.34 1.76 433 14.34 1.19 464 14.35 4.83 416 14.36 1.35 474 14.4 1.72 432 14.41 0.53 423 14.41 1.24 4157 14.45 1.55 437 14.68 2.07 4138 14.73 1.94 436 14.8 2.76 4168 14.83 1.38 453 14.94 0.03 412 14.99 3.08 Max. deviations for best ID is within recommended range. Chosen best chemical ID is suitable for programming the gauge. Selection of best generic ID for ROM based devices like bq274xx Device / Family #1 Generic Chem ID Device/ Voltage/ Chemistry max DOD error, % 312 bq27421-G1B: 4.3V LiCoO2 26.54 354 bq27411-G1C: 4.35V LiCoO2 37.43 3142 bq27421-G1D: 4.4V LiCoO2 43.35 128 bq27421-G1A: 4.2V LiCoO2 52.48 Best generic ID 312 Warning: Generic ID Deviation is so high that it is most likely due to anomaly in the data. Please check that data files have recomended format, units and test schedule Device / Family #2 Generic Chem ID Device/ Voltage/ Chemistry max DOD error, % 354 bq27621: (ALT_CHEM2) 4.35V LiCoO2 37.43 1202 bq27621: (default) 4.2V LiCoO2 37.84 1210 bq27621: (ALT_CHEM1) 4.3V LiCoO2 41.19 Best generic ID 354 Warning: Generic ID Deviation is so high that it is most likely due to anomaly in the data. Please check that data files have recomended format, units and test schedule Device / Family #3 Generic Chem ID Device/ Voltage/ Chemistry max DOD error, % 3230 bq27426: (default) 4.35V LiCoO2 35.41 1202 bq27426: (ALT_CHEM1) 4.2V LiCoO2 37.84 3142 bq27426: (ALT-CHEM2) 4.4V LiCoO2 43.35 Best generic ID 3230 Warning: Generic ID Deviation is so high that it is most likely due to anomaly in the data. Please check that data files have recomended format, units and test schedule