OPT3101EVM 出现 Operation I2C Register Read Failed.

Other Parts Discussed in Thread: OPT3101

#======

#Executing .. OPT3101/OPT3101EVMrevE3_Demo/devInit.py

#Start Time 2020-06-09 19:39:37.197000

Registers View - Reset property was not found

#================ ERRORS:0, WARNINGS:1 ================#

#================ ERRORS:0, WARNINGS:0 ================#

DEVR; Sending reset pulse to device

Operation I2C Register Read Failed.

Operation I2C Register Read Failed.

Operation I2C Register Read Failed.

                     ... ...

Operation I2C Register Read Failed.

Operation I2C Register Read Failed.

Internal electrical Crosstalk Correction

Operation I2C Register Read Failed.

#Error: %d format: a number is required, not NoneType

# "", line 8, in

# File "", line 146, in intXtalkCalib

# File "core\mDataTypes.py", line 408, in getValue

# File "core\mDataTypes.py", line 461, in readValue

# File "core\mDevice.py", line 383, in readProperty

# TypeError: %d format: a number is required, not NoneType

#

#

#================ ERRORS:145, WARNINGS:1 ================#

#Error: unsupported operand type(s) for &: 'NoneType' and 'int'

# "", line 4, in

# File "core\mDevice.py", line 319, in __setattr__

# File "core\mDataTypes.py", line 401, in setValue

# File "core\mDataTypes.py", line 439, in writeValue

# File "core\mDevice.py", line 367, in writeProperty

# TypeError: unsupported operand type(s) for &: 'NoneType' and 'int'

#

#

#================ ERRORS:1, WARNINGS:0 ================#

Operation I2C Register Read Failed.

#Error: %d format: a number is required, not NoneType

# "", line 1, in

# File "core\mDataTypes.py", line 408, in getValue

# File "core\mDataTypes.py", line 461, in readValue

# File "core\mDevice.py", line 383, in readProperty

# TypeError: %d format: a number is required, not NoneType

#

#

#================ ERRORS:2, WARNINGS:0 ================#

Operation I2C Register Read Failed.

#Error: %d format: a number is required, not NoneType

# "", line 657, in

# File "", line 22, in __init__

# File "", line 404, in readTIllum

# File "core\mDataTypes.py", line 408, in getValue

# File "core\mDataTypes.py", line 461, in readValue

# File "core\mDevice.py", line 383, in readProperty

# TypeError: %d format: a number is required, not NoneType

#

#

#================ ERRORS:2, WARNINGS:0 ================#

CAPE; Sending command to stop capture

No response from the Device

#Done executing .. OPT3101/OPT3101EVMrevE3_Demo/devInit.py

#End Time 2020-06-09 19:39:48.383000

#Execution Time = 11.1859998703 s

#================ ERRORS:1, WARNINGS:0 ================#